Compressed Air Foam Fire Extinguishing System and CAFS for Fire Trucks
Product Details:
Place of Origin: | China |
Brand Name: | CXFIRE |
Certification: | CCC, CE, EN, NFPA |
Model Number: | CAFS |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Unit |
---|---|
Price: | USD30000-USD80000 |
Packaging Details: | Standard Export Package and Delivery by Ship or Air |
Delivery Time: | 3-6 months |
Payment Terms: | T/T, L/C, D/A, D/P |
Supply Ability: | 1000 units per year |
Detail Information |
|||
Application: | Mounted On Fire Trucks | Mixed Liquid Flow Rate: | 550-3500 L/min. |
---|---|---|---|
Fire Nozzle Spraying Distance: | 25 Meters | Roof Monitor Spraying Distance: | 40 Meters |
Water Pump: | 1200-3600 L/min. Flow Rate | Air Compressor: | 5400-22000L/min. 37-160Kw |
Foam Mixing Ratio: | 0.1%-6% | Foam Pump: | 60L/min.-180L/min. |
Highlight: | CAFS Air Foam Fire Extinguishing System,CXFIRE Fire Extinguishing System,160Kw Fire Extinguishing System |
Product Description
1. CAFS-60/6000 Compressed Air Foam Fire Extinguishing System for Fire Trucks
Model | CAFS-60/6000 |
Flow Rate and Spray Performance |
1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 600 L/min; 2. The maximum mixed liquid flow rate is 850L/min; 3. The spraying distance of the fire nozzle is 24 meters; 4. The spraying distance of fire monitors is 40 meters. |
Water Pump |
1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa. |
Air Compressor |
1. The maximum flow is 5400L/min@0.7Mpa, the maximum power is 37KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device. |
Foam Mixing Ratio Unit |
1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min. |
Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. |
2. CAFS-900 Compressed Air Foam Fire Extinguishing System for Fire Trucks
Model | CAFS-900 |
Flow Rate and Spray Performance |
1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 550 L/min; 2. The maximum mixed liquid flow rate is 900L/min; 3. The spraying distance of the fire nozzle is 24 meters; 4. The spraying distance of fire monitors is 40 meters. |
Water Pump |
1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 1200L/min; Rated pressure: 1Mpa. |
Air Compressor |
1. The maximum flow is 5400L/min@0.7Mpa, the maximum power is 37KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device. |
Foam Mixing Ratio Unit |
1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min. |
Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. |
3. CAFS-1200 Compressed Air Foam Fire Extinguishing System for Fire Trucks
Model | CAFS-1200 |
Flow Rate and Spray Performance |
1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 1050 L/min; 2. The maximum mixed liquid flow rate is 1200L/min; 3. The spraying distance of the fire nozzle is 25 meters; 4. The spraying distance of fire monitors is 40 meters. |
Water Pump |
1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa. |
Air Compressor |
1. The maximum flow is 8400L/min@0.7Mpa, the maximum power is 55KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device. |
Foam Mixing Ratio Unit |
1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has three pumps combined into a pump group, and the total flow is 60L/min. |
Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. |
4. CAFS-MK3500 Compressed Air Foam Fire Extinguishing System for Fire Trucks
Model | CAFS-MK3500 |
Flow Rate and Spray Performance |
1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 3000 L/min; 2. The maximum mixed liquid flow rate is 3500L/min; 3. The spraying distance of the fire nozzle is 25 meters; 4. The spraying distance of fire monitors is 45 meters. |
Water Pump |
1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa. |
Air Compressor |
1. The maximum flow is 22,000L/min@0.7Mpa, the maximum power is 160KW; 2. The maximum working pressure is 1.3Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device. |
Foam Mixing Ratio Unit |
1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has nine pumps combined into a pump group, and the total flow is 180L/min. |
Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. |
5. Company Reference Pictures