Drager X-am8000 Multi Gas Detector with Dimensions H x W x D of 179 x 77 x 42 mm

Drager X-am8000 Multi Gas Detector with Dimensions H x W x D of 179 x 77 x 42 mm

Product Details:

Place of Origin: China
Brand Name: Drager
Certification: CCC, CE, EN, NFPA
Model Number: X-am8000

Payment & Shipping Terms:

Minimum Order Quantity: 1 Unit
Price: USD10000-USD20000
Packaging Details: Standard Export Package and Delivery by Ship or Air
Delivery Time: 1 month
Payment Terms: T/T, L/C, D/A, D/P
Supply Ability: 1000 units per year
Get Best Price Contact Now

Detail Information

Dimensions (H X W X D): 179 X77 X 42 Mm Weight: Approx. 495 G-550 G
Housing: Durable Two-component Housing Display: High-contrast Colour Display
Temperature: -20 ℃ To 50 ℃
High Light:

Drager X-am8000 Multi Gas Detector

,

42mm Multi Gas Detector

Product Description

Dräger X-am® 8000Multi-Gas Detector
Clearance measurement was never this easy and convenient:The 1 to 7 gas detector detects toxic and flammable gases as well as vapours and oxygen all at once - either in pump or diffusion mode.Innovative signalling design and handy assistant functions ensure complete safety throughout the process.

 

1.Technical Data

Dimensions (H x W x D) 179 x77 x 42 mm
Weight

Approx. 495 g, depending on sensor configuration, without strap, without pump

Approx. 550 g, depending on sensor configuration, without strap, with pump

Housing Durable two-component housing
Display High-contrast colour display
Temperature -20 ℃ to 50 ℃
Pressure

700 to 1,300 hPa (measuring function)

800 to 1,100 hPa (use in explosion-hazard areas)

Relative humidity 10 to 90 % (short-term up to 95 %)r.h.
Alarms Visual:

3 LED 'red'(gas alarms),

3 LED 'yellow'(device alarms)

Acoustic Multi-tone, typically 100 dB(A) at 30 cm
Vibration  
Ingress protection class IP 68
Energy supply Lithium-ion battery, rechargeable, inductive charging
Operating times (Diffusion) With CatEx and 3 EC sensors Typically 24 hours
With lR and 3 EC sensors Typically 22 hours
With 3 EC sensors Typically 120 hours
With CatEx, PlD and 3 EC sensors Typically 17 hours
With lR, PlD and 3 EC sensors Typically 16 hours
With CatEx-, IR- and 3 EC sensors Typically 14 hours
PID only Typically 42 hours
Charging times Typically 4 hours after use during a shift of max. 10 hours
Start-up times Typically <60 seconds for standard sensors
Data storage 24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing bythe second on all 7 channels: approx. 400 hours
Pump operation Max. hose length 45 m
Approvals Marking Explosion Protection:
ATEX /IECEX I M1, II 1G
Ex da ia l Ma, Ex da ia llC T4 Ga
EAC PO Ex da ia l Ma X
OEx da ia llC T4 Ga X
cCSAus Class l, Zone 0, AEx da ia llC T4 Ga
Class ll, Div 1, Gr. E,F,G
C22.2 No.152,ANSISA 12.13.01:2000
ANZEx Ex da ia l Ma, Ex da ia llC T4 Ga
Measurement Performance:

Explosion protection according ATEX:

EN 60079-29-1(CatEx 125 PR, CatEx125 PR Gas, (Dual) IR Ex, XXS H2 HC)

CatEx 125 PR and (Dual) IR Ex: methane,propane, n-nonane, etc.

The following applies to the CatEx 125 PR and approved gas "n-nonane": Only in conjunction with pump adapter "Nonan"part number: 3720225

Oxygen deficieny/excess oxygen:

EN 50104 (XXS O,/ XXS O,PR)

Toxic gases:

EN 45544-1, EN 45544-2,EN 45544-3(XXS H,S LC, XXS CO LC, (Dual) IR COz)

Software: EN 50271
Directives 2014/34/EU(ATEX)
2014/30/EU(EMV)
2011/65/EU(RoHS)
2014/90/EU (MED)
Marine Approval DNV GL
Manufacturer´s warranty 3 years for the device
1 year for the power supply
Sensors: see DrägerSensor"& Portable Instruments Handbook

 

2. Pictures for Reference

Drager X-am8000 Multi Gas Detector with Dimensions H x W x D of 179 x 77 x 42 mm 0 Drager X-am8000 Multi Gas Detector with Dimensions H x W x D of 179 x 77 x 42 mm 1 Drager X-am8000 Multi Gas Detector with Dimensions H x W x D of 179 x 77 x 42 mm 2 

   
 

Want to Know more details about this product
I am interested in Drager X-am8000 Multi Gas Detector with Dimensions H x W x D of 179 x 77 x 42 mm could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.